Active work · Palm Desert
Surgery Center Electrical in Palm Desert
A medical office in Palm Desert is being converted into a surgery center, and we’re the electrical contractor. The old system came out, and a new 120/208V main switchboard, a new underground service path, sub panels and code-required backup power are going in, wired to commercial standards.
- Location
- Palm Desert
- Project type
- Commercial: medical office converted into a surgery center
- Status
- Active work, started December 2025
- Service
- New 120/208V main metered switchboard, sub panels and a new service path from the utility transformer
- Backup power
- Code-required; the design is moving from a generator to a battery system
- Contractor
- Power On Solutions LLC, licensed C-10 electrical contractor (CSLB #1151468)
Project video The work so far
Behind the walls Built for a medical space, and for the next service call
For a GC, an owner or an engineer, how the wiring goes in matters as much as what’s on the plans. Here’s what’s going into this space so far.
- New runs went into the trenches before the floor was closed, so the slab is opened once.
- Main runs in EMT conduit, routed clean above the ceiling for future service access.
- Dedicated circuits for the equipment a surgery center runs on: rooftop units, mini-splits, HEPA filtration and surgical arm lights.
- Backup power planned with the general contractor and the engineer, so the panels and the transfer switch match what the building actually needs to keep running.
Scope of work What we’re doing
- Demo of the old electrical throughout the former medical office.
- New 120/208V main metered switchboard.
- New service path from the utility transformer, with underground and attic conduit runs.
- New sub panels.
- Transfer switch for the code-required backup power.
- New wiring, circuits, devices and lighting throughout.
- Circuits for the rooftop units (RTUs), mini-splits, HEPA filtration units and surgical arm lights.
- Load review for the backup power, with the general contractor and the engineer.
How we work The challenge: backup power
A surgery center needs code-required backup power. The first design called for a diesel generator, and we reviewed its size against the plans and our own site notes. The generator’s location wasn’t approved, so the design is moving to a battery backup system. The engineer is revising the drawings, and the owner asked for our input on which loads the battery system needs to carry.
-
01Size it
Generator size reviewed against the plans and site notes.
-
02Placement
The generator location was not approved.
-
03Rethink
A battery backup system proposed instead.
-
04Redraw
Engineer revising the drawings, with our input on the loads.
Palm Desert and beyond More projects.
All projects-
Electrical Troubleshooting & Repair — Palm Desert
Palm Desert Feeder Circuit Repair
Electrical troubleshooting and feeder circuit repair in Palm Desert, focused on restoring reliable service.
-
Clean Conduit Installation — Palm Desert
Palm Desert Bank Remodel
Clean conduit routed for a Palm Desert bank remodel, keeping the rough-in organized and serviceable.
-
Outdoor Lighting — Palm Desert
Palm Desert HOA Lighting Maintenance
Palm Desert HOA lighting maintenance with attention to exterior exposure and serviceability.
-
3 photos
Solar Electrical — Indian Wells
Solar system troubleshooting
Troubleshooting a home solar system in Indian Wells: meter readings and checks at the service panel.
Get started Planning a commercial or medical build-out in the Coachella Valley?
Licensed C-10 contractor. Send us your plans or set up a walkthrough and we’ll get you a bid.